CVE REMEDIATION GUIDE
Review reviewCriticalResearch in progress

CVE-2026-4769 remediation guide

WAGO 0765-110x/0100-0000, 0765-120x/0100-0000, 0765-150x/0100-0000

Certain devices in the WAGO System I/O Field series activate an internal diagnostic capability during the initial startup sequence. This functionality is not formally documented and becomes accessible without authentication for a brief period in the early boot phase. During this window, an unauthenticated remote attacker can gain access to the internal system processes, resulting in full system compromise.

Open CVE record
Research in progress

A verified fixed-version field is not available. Use the linked NVD and supporting references, then confirm the vendor-supported path before changing production systems.

ProductWAGO 0765-110x/0100-0000, 0765-120x/0100-0000, 0765-150x/0100-0000
Affected versions>= 1.0.0.0 < 1.2.1.100, >= 1.0.0.0 < 1.2.7.100, >= 1.0.0.0 < 1.2.7.103, >= 1.0.0.0 < 1.2.1.102, >= 1.0.0.0 < 1.2.5.101
Fixed versionsNo verified fixed-version field is available yet
Priority basisReview · CVSS 9.3 · EPSS 0.45%
01

Identify the affected asset

Confirm whether WAGO 0765-110x/0100-0000, 0765-120x/0100-0000, 0765-150x/0100-0000 is installed, record the deployed version and installation path, and identify exposed interfaces.

  • Record the product name, package or appliance identifier, and installed version.
  • Identify internet-facing, administrative, API, and internal access paths.
  • Preserve the pre-change configuration and relevant service logs.
02

Validate the affected-version match

Compare the deployed version with the affected range: >= 1.0.0.0 < 1.2.1.100, >= 1.0.0.0 < 1.2.7.100, >= 1.0.0.0 < 1.2.7.103, >= 1.0.0.0 < 1.2.1.102, >= 1.0.0.0 < 1.2.5.101. Treat incomplete inventory results as unresolved.

03

Prioritize with independent signals

The CVSS severity warrants an early asset and exposure review. Combine this signal with asset criticality, exposure, compensating controls, and business impact.

04

Apply supported remediation

Follow the vendor advisory or supported update path. Current fixed-version status: No verified fixed-version field is available yet. Preserve configuration and rollback material before change.

05

Verify the result

Confirm the resulting version, service health, authentication and access paths, monitoring coverage, and relevant security logs.

  • Confirm the expected version and package state.
  • Run a functional health check for critical service paths.
  • Review authentication, error, application, and security monitoring logs.
  • Reassess exposure if the supported fix cannot be applied.

Operational boundary

This page does not replace the vendor advisory, support contract, change-management process, or recovery plan. Do not infer that an asset is unaffected from an incomplete inventory query or a missing fixed-version field.