Unisys WebPerfect Image Suite, webperfect image suite

Unisys WebPerfect Image Suite versions 3.0.3960.22810 and 3.0.3960.22604 expose an unauthenticated WCF SOAP endpoint on TCP port 1208 that accepts unsanitized file paths in the ReadLicense action's LFName parameter, allowing remote attackers to trigger SMB connections and leak NTLMv2 machine-account hashes. Attackers can submit crafted SOAP requests with UNC paths to force the server to initiate outbound SMB connections, exposing authentication credentials that may be relayed for privilege escalation or lateral movement within the network.

CVSS
7
EPSS
0.62%
46.2% percentile
CISA KEV
Not listed
Published
2026.04.15
PRIORITY ASSESSMENT

Review review

The CVSS severity warrants an early asset and exposure review.

Known exploitationNot established by KEV
Exploit probability0.62%
Technical severityCVSS 7

Vulnerability overview

Unisys WebPerfect Image Suite versions 3.0.3960.22810 and 3.0.3960.22604 expose an unauthenticated WCF SOAP endpoint on TCP port 1208 that accepts unsanitized file paths in the ReadLicense action's LFName parameter, allowing remote attackers to trigger SMB connections and leak NTLMv2 machine-account hashes. Attackers can submit crafted SOAP requests with UNC paths to force the server to initiate outbound SMB connections, exposing authentication credentials that may be relayed for privilege escalation or lateral movement within the network.

Affected product and versions

Product
Unisys WebPerfect Image Suite, webperfect image suite
Affected versions
>= 3.0.3960.22810, >= 3.0.3960.22604, 3.0.3960.22604, 3.0.3960.22810
Fixed versions
No verified fixed-version field is available yet

Recommended response sequence

Confirm exposure before applying a vendor-supported change.

Full remediation guide
  1. 1
    Identify

    Confirm that Unisys WebPerfect Image Suite, webperfect image suite and an affected version are present.

  2. 2
    Prioritize

    Combine exploitation signals with asset exposure and business criticality.

  3. 3
    Remediate

    Follow the vendor advisory or supported update path and preserve rollback options.

  4. 4
    Verify

    Recheck the version, service health, access paths, and relevant logs.

Technical data

CVSS vector
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE