Review reviewHigh

CVE-2026-33794

Juniper Networks Junos OS Evolved, junos os evolved, ptx1000-72q

An Improper Check for Unusual or Exceptional Conditions vulnerability in the advanced forwarding toolkit (evo-aftmand) of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated network-based attacker generating continuous routing updates, resulting in unilist ECMP routes, to crash the evo-aftmand process on the PFE, leading to a Denial-of-Service (DoS). The conditions required for successful exploitation are based on a sequence of events that are outside an attacker's direct control. Unified list (unilist) ECMP routes are a specific ECMP behavior where multiple equal-cost...

CVSS
8.2
EPSS
0.24%
14.7% percentile
CISA KEV
Not listed
Published
2026.07.10
PRIORITY ASSESSMENT

Review review

The CVSS severity warrants an early asset and exposure review.

Known exploitationNot established by KEV
Exploit probability0.24%
Technical severityCVSS 8.2

Vulnerability overview

An Improper Check for Unusual or Exceptional Conditions vulnerability in the advanced forwarding toolkit (evo-aftmand) of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated network-based attacker generating continuous routing updates, resulting in unilist ECMP routes, to crash the evo-aftmand process on the PFE, leading to a Denial-of-Service (DoS). The conditions required for successful exploitation are based on a sequence of events that are outside an attacker's direct control. Unified list (unilist) ECMP routes are a specific ECMP behavior where multiple equal-cost...

Affected product and versions

Product
Juniper Networks Junos OS Evolved, junos os evolved, ptx1000-72q
Affected versions
>= 24.4R2-EVO < 24.4R2-S3-EVO, >= 25.2 < 25.2R2, 25.2R2-EVO, 24.4, 25.2
Fixed versions
No verified fixed-version field is available yet

Recommended response sequence

Confirm exposure before applying a vendor-supported change.

Full remediation guide
  1. 1
    Identify

    Confirm that Juniper Networks Junos OS Evolved, junos os evolved, ptx1000-72q and an affected version are present.

  2. 2
    Prioritize

    Combine exploitation signals with asset exposure and business criticality.

  3. 3
    Remediate

    Follow the vendor advisory or supported update path and preserve rollback options.

  4. 4
    Verify

    Recheck the version, service health, access paths, and relevant logs.