Review reviewHigh

CVE-2026-15480

Trendnet TEW-635BRM

A vulnerability was identified in Trendnet TEW-635BRM up to 1.00.03. This affects the function start_httpd of the file /sbin/rc of the component Web Service. Such manipulation of the argument device_name leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor explains: "We are unable to confirm if the vulnerability exists. This item has been EOL since 2011. We will make an official announcement of possible vulnerabilities, and recommend users to switch devices." This vulnerability only affects products that a...

CVSS
7.4
EPSS
0.47%
38.4% percentile
CISA KEV
Not listed
Published
2026.07.12
PRIORITY ASSESSMENT

Review review

The CVSS severity warrants an early asset and exposure review.

Known exploitationNot established by KEV
Exploit probability0.47%
Technical severityCVSS 7.4

Vulnerability overview

A vulnerability was identified in Trendnet TEW-635BRM up to 1.00.03. This affects the function start_httpd of the file /sbin/rc of the component Web Service. Such manipulation of the argument device_name leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor explains: "We are unable to confirm if the vulnerability exists. This item has been EOL since 2011. We will make an official announcement of possible vulnerabilities, and recommend users to switch devices." This vulnerability only affects products that a...

Affected product and versions

Product
Trendnet TEW-635BRM
Affected versions
>= 1.00.03
Fixed versions
No verified fixed-version field is available yet

Recommended response sequence

Confirm exposure before applying a vendor-supported change.

Full remediation guide
  1. 1
    Identify

    Confirm that Trendnet TEW-635BRM and an affected version are present.

  2. 2
    Prioritize

    Combine exploitation signals with asset exposure and business criticality.

  3. 3
    Remediate

    Follow the vendor advisory or supported update path and preserve rollback options.

  4. 4
    Verify

    Recheck the version, service health, access paths, and relevant logs.

Technical data

CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE
CWE-119, CWE-121