CVE REMEDIATION GUIDE
Review reviewHighResearch in progress

CVE-2026-11826 remediation guide

openplcproject OpenPLC_v3

OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent...

Open CVE record
Research in progress

A verified fixed-version field is not available. Use the linked NVD and supporting references, then confirm the vendor-supported path before changing production systems.

Productopenplcproject OpenPLC_v3
Affected versions<= b470206
Fixed versionsNo verified fixed-version field is available yet
Priority basisReview · CVSS 8.7 · EPSS 0.42%
01

Identify the affected asset

Confirm whether openplcproject OpenPLC_v3 is installed, record the deployed version and installation path, and identify exposed interfaces.

  • Record the product name, package or appliance identifier, and installed version.
  • Identify internet-facing, administrative, API, and internal access paths.
  • Preserve the pre-change configuration and relevant service logs.
02

Validate the affected-version match

Compare the deployed version with the affected range: <= b470206. Treat incomplete inventory results as unresolved.

03

Prioritize with independent signals

The CVSS severity warrants an early asset and exposure review. Combine this signal with asset criticality, exposure, compensating controls, and business impact.

04

Apply supported remediation

Follow the vendor advisory or supported update path. Current fixed-version status: No verified fixed-version field is available yet. Preserve configuration and rollback material before change.

05

Verify the result

Confirm the resulting version, service health, authentication and access paths, monitoring coverage, and relevant security logs.

  • Confirm the expected version and package state.
  • Run a functional health check for critical service paths.
  • Review authentication, error, application, and security monitoring logs.
  • Reassess exposure if the supported fix cannot be applied.

Operational boundary

This page does not replace the vendor advisory, support contract, change-management process, or recovery plan. Do not infer that an asset is unaffected from an incomplete inventory query or a missing fixed-version field.