Review reviewCritical

CVE-2026-11429

Altium Altium Enterprise Server, Altium 365

Two endpoints in the Vault Service ScriptsController, shared by Altium Enterprise Server and Altium 365, accept file uploads where a user-supplied filename component is used to construct the destination path without validation, allowing arbitrary files to be written to any location writable by the service account. Because the file write operation completes before authentication is validated, the vulnerability can be exploited without any credentials, session, or prior knowledge of the system. An unauthenticated network attacker can use this primitive to place executable content in directori...

CVSS
10
EPSS
1.15%
63.6% percentile
CISA KEV
Not listed
Published
2026.06.06
PRIORITY ASSESSMENT

Review review

The CVSS severity warrants an early asset and exposure review.

Known exploitationNot established by KEV
Exploit probability1.15%
Technical severityCVSS 10

Vulnerability overview

Two endpoints in the Vault Service ScriptsController, shared by Altium Enterprise Server and Altium 365, accept file uploads where a user-supplied filename component is used to construct the destination path without validation, allowing arbitrary files to be written to any location writable by the service account. Because the file write operation completes before authentication is validated, the vulnerability can be exploited without any credentials, session, or prior knowledge of the system. An unauthenticated network attacker can use this primitive to place executable content in directori...

Affected product and versions

Product
Altium Altium Enterprise Server, Altium 365
Affected versions
< 8.1.1, >= unspecified
Fixed versions
No verified fixed-version field is available yet

Recommended response sequence

Confirm exposure before applying a vendor-supported change.

Full remediation guide
  1. 1
    Identify

    Confirm that Altium Altium Enterprise Server, Altium 365 and an affected version are present.

  2. 2
    Prioritize

    Combine exploitation signals with asset exposure and business criticality.

  3. 3
    Remediate

    Follow the vendor advisory or supported update path and preserve rollback options.

  4. 4
    Verify

    Recheck the version, service health, access paths, and relevant logs.

Technical data

CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE
CWE-22, CWE-306