CVE-2022-4992

Dräger Infinity Acute Care System, Standalone Infinity M540 patient monitor

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.

CVSS
8.8
EPSS
0.16%
5.68% percentile
CISA KEV
Not listed
Published
2026.06.03
PRIORITY ASSESSMENT

Review review

The CVSS severity warrants an early asset and exposure review.

Known exploitationNot established by KEV
Exploit probability0.16%
Technical severityCVSS 8.8

Vulnerability overview

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.

Affected product and versions

Product
Dräger Infinity Acute Care System, Standalone Infinity M540 patient monitor
Affected versions
< VG4.2, < VG4.1.1, < VG4.0.3
Fixed versions
No verified fixed-version field is available yet

Recommended response sequence

Confirm exposure before applying a vendor-supported change.

Full remediation guide
  1. 1
    Identify

    Confirm that Dräger Infinity Acute Care System, Standalone Infinity M540 patient monitor and an affected version are present.

  2. 2
    Prioritize

    Combine exploitation signals with asset exposure and business criticality.

  3. 3
    Remediate

    Follow the vendor advisory or supported update path and preserve rollback options.

  4. 4
    Verify

    Recheck the version, service health, access paths, and relevant logs.

Technical data

CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE
CWE-345